Figure 5. Illustration of pre-charged accumulator conditions and conditions under maximum and minimum system pressures.

Fluid Energy Controls - FEC International

or

Fluid Energy Controls - FEC International

Fluid Energy Controls - FEC International
Figure 6. Actual photos of API 614 lubeoil console featuring 120 gallon, 500 psi accumulator designed for installation within gas turbine unit within power
generation plant.
Fluid Energy Controls - FEC International

 

P2 = Maximum system design operating pressure, psia.
V2 = The compressed volume of gas at maximum
system’s pressure P2 , cu. in.
P3 = The minimum system pressure, psia, at which
the additional volume V3 of lube oil is required.
V3 = The expanded volume of gas at minimum system pressure P3, cu. in.
Based on a Boyle’s Law for the following states:
P1 V1n = P2 V2n = P3 V3n
or
V1 (P1)1/ n = V2 (P2)1/ n = V3 (P3)1/ n
and
Vx= V3 - V2,

From Boyle’s Law for the changing conditions from
the fully charged accumulator to the discharge state:
V2 (P2)1/ n = V3 (P3)1/ n
and
V3= Vx + V2,
or
V2 (P2)1/ n = (P3)1/ n(Vx + V2),

and finally with respect to V2:

V2 =              (P3)1/ n Vx
            -------------------------------
                   (P2)1/ n - (P3)1/ n

From Boyle’s Law for the changing conditions from
the pre-charged state to the fully charged accumulator:
(P1)1/ n V1 = (P2)1/ n V2

or