  Accumulators:

 
 
 
 
 
Bladder Accumulators
for Turbomachinery
Lube Oil Sytems
Fluid Energy Controls - FEC International Bladder Accumulators
rated to 3000 psi
Fluid Energy Controls - FEC International LOSA Article Fluid Energy Controls - FEC International Stainless Steel Accumulators
Accumulators > Lube Oil Systems > Bladder Accumulators for Turbomachinery Lube Oil Systems - Pages 1 | 2 | 3
Lube-Oil System Accumulators — Stainless Steel Construction
850 and 1020 PSI DESIGN PRESSURE      
Standard Features:
  • 304 Stainless Steel construction.
  • Designed and stamped per ASME Code Section VIII, Div. 1. European CE, Canadian CRN, Brazilian NR-13, Chinese SELO, and Malaysian DOSH certifications also available.
  • National Board Registered.
  • API Standard 614.
  • 850 and 1020 PSI maximum design pressure.
  • Temperature service -20°F to +200°F.
  • Safe, tamper proof design.
  • Buna-N compound bladder. (Other bladder compounds available upon request.)
  • 2" NPT liquid connection.
NOMINAL
SIZE
PART
NO.
GAS
VOLUME
CU. IN.
EST. WT.
DRY
LBS.
“A”
DIM.
IN.
“B”
DIM.
IN.
“C”
DIM.
IN.
850 PSI DESIGN PRESSURE
21/2 Gal.
7294000
555
65
217/8
151/2
85/8
5 Gal
7295000
1095
96
34
271/2
85/8
10 Gal
7296000
2080
150
545/8
481/4
85/8
11 Gal
7297000
2360
161
603/4
541/4
85/8
15 Gal
7298000
3460
216
741/2
687/8
85/8
1020 PSI DESIGN PRESSURE
21/2 Gal.
7301000
555
65
217/8
151/2
85/8
5 Gal
7302000
1095
96
34
271/2
85/8
10 Gal
7303000
2080
150
545/8
481/4
85/8
11 Gal
7304000
2360
161
603/4
541/4
85/8
15 Gal
7305000
3460
216
741/2
687/8
85/8
Note: All dimensions and weights are for general information only. Since products are in a continual state of refinement, please verify all critical dimensions with Fluid Energy Controls, Inc. Note: other materials of construction, pressure and connection are available upon request. Warranty: Fluid Energy Controls, Inc. guaranteed its products for materials and workmanship for one full year from the date of purchase, but because we cannot anticipate or control the many different conditions under which this information and our products may
be used, we do not guarantee the applicability or suitability of our products in any given situation. Users of our products should make their own tests to determine the suitability of each product for their particular purposes. The products discussed are sold with a limited warranty and buyer assumes all responsibility for loss or damage arising from the handling and use of our products whether done in accordance with directions or not. Also, statements concerning the possible use of our products are not intended as recommendations to use our products.
  FLUID ENERGY CONTROLS